Datasheet
THS4001
270-MHz HIGH-SPEED AMPLIFIER
SLOS206A– DECEMBER 1997 – REVISED MARCH 1999
10
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS
Figure 18
TOTAL HARMONIC DISTORTION
vs
FREQUENCY
1
f – Frequency – MHz
THD – Total Harmonic Distortion – dB
10
0.5
–55
–65
–75
–85
–50
–60
–70
–80
2 nd Harmonic
3 rd Harmonic
G = +2
V
IN
= 1 V(
PP)
V
CC
= ±15 V
R
L
= 150 Ω