Datasheet

www.ti.com
RECOMMENDED OPERATING CONDITIONS
ABSOLUTE MAXIMUM RATINGS
THS3092
THS3096
SLOS428B DECEMBER 2003 REVISED FEBRUARY 2006
MIN MAX UNIT
Dual supply ±5 ±15
Supply voltage V
Single supply 10 30
Operating free-air temperature, T
A
-40 85 °C
over operating free-air temperature (unless otherwise noted)
(1)
UNIT
Supply voltage, V
S-
to V
S+
33 V
Input voltage, V
I
± V
S
Differential input voltage, V
ID
± 4 V
Output current, I
O
350 mA
Continuous power dissipation See Dissipation Ratings Table
Maximum junction temperature, T
J
150°C
Maximum junction temperature, continuous operation, long term reliability, T
J
(2)
125°C
Storage temperature, T
stg
-65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 300°C
ESD ratings:
HBM 2000
CDM 1500
MM 150
(1) The absolute maximum ratings under any condition is limited by the constraints of the silicon process. Stresses above these ratings may
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.
(2) The maximum junction temperature for continuous operation is limited by package constraints. Operation above this temperature may
result in reduced reliability and/or lifetime of the device.
3
Submit Documentation Feedback