Datasheet

RECOMMENDED OPERATING CONDITIONS
ABSOLUTE MAXIMUM RATINGS
THS3091
THS3095
www.ti.com
........................................................................................................................................ SLOS423G SEPTEMBER 2003 REVISED OCTOBER 2008
MIN MAX UNIT
Dual supply ± 5 ± 15
Supply voltage V
Single supply 10 30
T
A
Operating free-air temperature 40 85 ° C
over operating free-air temperature (unless otherwise noted)
(1)
UNIT
V
S-
to V
S+
Supply voltage 33 V
V
I
Input voltage ± V
S
V
ID
Differential input voltage ± 4 V
I
O
Output current 350 mA
Continuous power dissipation See Dissipation Ratings Table
T
J
Maximum junction temperature, 150 ° C
T
J
(2)
Maximum junction temperature, continuous operation, long-term reliability 125 ° C
T
stg
Storage temperature 65 ° C to 150 ° C
Lead temperature
(3)
HBM 2000
ESD ratings CDM 1500
MM 150
(1) The absolute maximum ratings under any condition is limited by the constraints of the silicon process. Stresses above these ratings may
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.
(2) The maximum junction temperature for continuous operation is limited by package constraints. Operation above this temperature may
result in reduced reliability and/or lifetime of the device.
(3) See the MSL/Reflow Rating information provided with the material, or see TI ' s web site at www.ti.com for the latest information.
Copyright © 2003 2008, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): THS3091 THS3095