SLAS248D − DECEMBER 1999 − REVISED SEPTEMBER 2005
www.ti.com
8
PARAMETER MEASUREMENT INFORMATION
read timing (15-pF load)
PARAMETER MIN TYP MAX UNIT
t
su(OE−ACS)
Address and chip select setup time 4 ns
t
en
Output enable 15 ns
t
dis
Output disable 10 ns
t
h(A)
Address hold time 1 ns
t
h(CS)
Chip select hold time 0 ns
NOTE: All timing parameters refer to a 50% level.
DATA
ADDRESS
CS
OE
D[13:0]
O V
A[1:0]
X X
t
su(OE−ACS)
t
en
t
h(CS)
t
dis
t
h(A)
Figure 2. Read Timing