Datasheet

P00 A
0.7 × V
CC
0.3 × V
CC
SCL
P17
t
pv
(see Note A)
Slave
ACK
Unstable
Data
Last Stable Bit
SDA
Pn
Pn
WRITE MODE (R/W = 0)
P00 A
0.7 × V
CC
0.3 × V
CC
SCL
P17
0.7 × V
CC
0.3 × V
CC
t
ps
t
ph
READ MODE (R/W = 1)
DUT
GND
C
L
= 100 pF
P-PORT LOAD CONFIGURATION
Pn
TCA9555
SCPS200A JULY 2009 REVISED JULY 2009 ..............................................................................................................................................................
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
A. C
L
includes probe and jig capacitance.
B. t
pv
is measured from 0.7 × V
CC
on SCL to 50% I/O (Pn) output.
C. All inputs are supplied by generators having the following characteristics: PRR 10 MHz, Z
O
= 50 , t
r
/t
f
30 ns.
D. The outputs are measured one at a time, with one transition per measurement.
E. All parameters and waveforms are not applicable to all devices.
Figure 13. P-Port Load Circuit and Voltage Waveforms
20 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TCA9555