Datasheet
Table Of Contents
- FEATURES
- DESCRIPTION/ORDERING INFORMATION
- DESCRIPTION/ORDERING INFORMATION (continued)
- Absolute Maximum Ratings
- Recommended Operating Conditions
- Electrical Characteristics
- I2C Interface Timing Requirements
- Switching Characteristics
- TYPICAL CHARACTERISTICS
- PARAMETER MEASUREMENT INFORMATION
- APPLICATION INFORMATION
- REVISION HISTORY

P0 A
0.7 × V
CC
0.3 × V
CC
SCL
P7
t
pv
(see Note B)
Slave
ACK
Unstable
Data
Last Stable Bit
SDA
P
n
P
n
WRITE MODE (R/W = 0)
P0 A
0.7 × V
CC
0.3 × V
CC
SCL
P7
0.7 × V
CC
0.3 × V
CC
t
ps
t
ph
READ MODE (R/W
= 1)
P-PORT LOAD CONFIGURATION
DUT
C
L
= 50 pF
(see Note A)
Pn
2 × V
CC
500 W
500 W
1.5 V
TCA9554
www.ti.com
SCPS233A –NOVEMBER 2011–REVISED MARCH 2012
PARAMETER MEASUREMENT INFORMATION (continued)
A. C
L
includes probe and jig capacitance.
B. t
pv
is measured from 0.7 × V
CC
on SCL to 50% I/O pin output.
C. All inputs are supplied by generators having the following characteristics: PRR ≤ 10 MHz, Z
O
= 50 Ω, t
r
/t
f
≤ 30 ns.
D. The outputs are measured one at a time, with one transition per measurement.
E. All parameters and waveforms are not applicable to all devices.
Figure 14. P-Port Load Circuit and Voltage Waveforms
Copyright © 2011–2012, Texas Instruments Incorporated Submit Documentation Feedback 19
Product Folder Link(s): TCA9554