Datasheet
Jumpers and Control Utilities on Input-USB Board3
www.ti.com
5 Jumpers and Control Utilities on Input-USB Board3
5.1 RCA/OPTICAL Jumpers
• ADC1: The default is to have a jumper installed on pins 2 and 3. To input an external I2S data signal,
remove the jumper and connect the new I2S source using pins 3 and 4.
• MCLK: The default is to have a jumper installed on pins 2 and 3. To input an external MCLK signal,
remove the jumper and connect the new MCLK source using pins 3 and 4.
• SCLK: The default is to have a jumper installed on pins 2 and 3. To input an external SCLK signal,
remove the jumper and connect the new SCLK source using pins 3 and 4.
• LRCLK: The default is to have a jumper installed on pins 2 and 3. To input an external LRCLK signal,
remove the jumper and connect the new LRCLK source using pins 3 and 4.
• JP300 and JP301: Install for analog inputs of less than 1-V
RMS
; leave uninstalled for analog inputs from
1-V
RMS
to 2-V
RMS
.
• All other jumpers on the Input-USB Board3 have no functionality with the TAS5721-TAS5723EVM.
5.2 Switches
• S1 (RESET): Pressing the RESET switch resets the TAS572X device
• S2 (COAX/OPTO): Determines which digital input to use, RCA or optical.
• S3 (VOL DOWN): This switch has no function with the EVM
• S4 (VOL UP): This switch has no function with the EVM
• S5 (USB MUTE): This switch has no function with the EVM
• S6 (MUTE): This switch has no function with the EVM
• S7 (I2S SELECT): Selects the I2S source. When using the OPTO or RCA inputs, flip this switch to
SPDIF.
• S8 (PDN): Pressing PDN powers down the TAS572X.
5.3 LED Indicators
• 12 V: 12-V power is valid
• 5 V: 5-V power is valid
• 3.3 V: 3.3-V power is valid
• SPDIF-LOCK: SPDIF signal locked
• COAX: S2 is set to the COAX position
• OPTO: S2 is set to the OPTO position
• USB: S7 is set to the USB position
• SPDIF: S7 is set to the SPDIF position
• FAULT: not used with the EVM
• PDN: indicates that the PDN switch is asserted
• MUTE: not used with the EVM
• SHUTDOWN: not used with the EVM
• OTW: not used with the EVM
• DIGITAL: indicates that the digital input source is active
• ANALOG: indicates that the analog input source is active
10
TAS5721-TAS5723EVM Evaluation Module SLOU346–July 2012
Copyright © 2012, Texas Instruments Incorporated