Datasheet
INPUT MULTIPLEXER REGISTER (0x20)
TAS5716
SLOS569 – JANUARY 2009 ...............................................................................................................................................................................................
www.ti.com
The hex value for each nibble is the channel number. For each input multiplexer, any input from SDIN1, SDIN2
can be mapped to any internal TAS5716 channel.
Table 20. Input Multiplexer Register (0x20)
D31 D30 D29 D28 D27 D26 D25 D24 FUNCTION
0 0 0 0 0 0 0 0 Reserved = 0x00
(1)
D23 D22 D21 D20 D19 D18 D17 D16 FUNCTION
0 – – – – – – – Channel-1 AD mode
1 – – – – – – – Channel-1 BD mode
(1)
– 0 0 0 – – – – SDIN1-L to channel 1
(1)
– 0 0 1 – – – – SDIN1-R to channel 1
– 0 1 0 – – – – SDIN2-L to channel 1
– 0 1 1 – – – – SDIN2-R to channel 1
– 1 0 0 – – – – Reserved
– 1 0 1 – – – – Reserved
– 1 1 0 – – – – Ground (0) to channel 1
– 1 1 1 – – – – Reserved
– – – – 0 – – – Channel 2 AD mode
– – – – 1 – – – Channel 2 BD mode
(1)
– – – – – 0 0 0 SDIN1-L to channel 2
– – – – – 0 0 1 SDIN1-R to channel 2
(1)
– – – – – 0 1 0 SDIN2-L to channel 2
– – – – – 0 1 1 SDIN2-R to channel 2
– – – – – 1 0 0 Reserved
– – – – – 1 0 1 Reserved
– – – – – 1 1 0 Ground (0) to channel 2
– – – – – 1 1 1 Reserved
(1) Default values are in bold.
54 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TAS5716