START/STOP PERIOD REGISTER (0x1A)
TAS5716
SLOS569 – JANUARY 2009 ...............................................................................................................................................................................................
www.ti.com
This register is used to control the soft-start and soft-stop period when starting up or shutting down channels.
The value in this register determines the time for which the PWM inputs switch at 50% duty cycle. This helps
reduce pops and clicks at start-up and shutdown.
D7 is used to configure the output stage in a bridge-tied mode or a single-ended mode.
Table 17. Start/Stop Period Register (0x1A)
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 – – – – – – – Bridge-tied load (BTL)
(1)
1 – – – – – – – Single-ended load (SE)
– – – 0 0 – – – No 50% duty cycle start/stop period
– – – 0 1 0 0 0 16.5-ms 50% duty cycle start/stop period
– – – 0 1 0 0 1 23.9-ms 50% duty cycle start/stop period
– – – 0 1 0 1 0 31.4-ms 50% duty cycle start/stop period
(1)
– – – 0 1 0 1 1 40.4-ms 50% duty cycle start/stop period
– – – 0 1 1 0 0 53.9-ms 50% duty cycle start/stop period
– – – 0 1 1 0 1 70.3-ms 50% duty cycle start/stop period
– – – 0 1 1 1 0 94.2-ms 50% duty cycle start/stop period
– – – 0 1 1 1 1 125.7-ms 50% duty cycle start/stop period
– – – 1 0 0 0 0 164.6-ms 50% duty cycle start/stop period
– – – 1 0 0 0 1 239.4-ms 50% duty cycle start/stop period
– – – 1 0 0 1 0 314.2-ms 50% duty cycle start/stop period
– – – 1 0 0 1 1 403.9-ms 50% duty cycle start/stop period
– – – 1 0 1 0 0 538.6-ms 50% duty cycle start/stop period
– – – 1 0 1 0 1 703.1-ms 50% duty cycle start/stop period
– – – 1 0 1 1 0 942.5-ms 50% duty cycle start/stop period
– – – 1 0 1 1 1 1256.6-ms 50% duty cycle start/stop period
– – – 1 1 0 0 0 1728.1-ms 50% duty cycle start/stop period
– – – 1 1 0 0 1 2513.6-ms 50% duty cycle start/stop period
– – – 1 1 0 1 0 3299.1-ms 50% duty cycle start/stop period
– – – 1 1 0 1 1 4241.7-ms 50% duty cycle start/stop period
– – – 1 1 1 0 0 5655.6-ms 50% duty cycle start/stop period
– – – 1 1 1 0 1 7383.7-ms 50% duty cycle start/stop period
– – – 1 1 1 1 0 9897.3-ms 50% duty cycle start/stop period
– – – 1 1 1 1 1 13,196.4-ms 50% duty cycle start/stop period
(1) Default values are in bold.