Datasheet
TAS5715
www.ti.com
SLOS645 –AUGUST 2010
DRC AND DC DETECT CONTROL (0x46)
Table 23. DRC AND DC DETECT CONTROL
D31 D30 D29 D28 D27 D26 D25 D24 FUNCTION
0 0 0 0 0 0 0 0 Reserved
(1)
D23 D22 D21 D20 D19 D18 D17 D16 FUNCTION
0 0 0 0 0 0 0 0 Reserved
(1)
D15 D14 D13 D12 D11 D10 D9 D8 FUNCTION
0 0 0 0 0 – – – Reserved
(1)
– – – – – 0 – – PWM DC detect disabled
– – – – – 1 – – PWM DC detect enabled
– – – – – – 0 – EQ CRC detect disabled
– – – – – – 1 – EQ CRC detect enabled
– – – – – – – 0 DRC CRC detect disabled
– – – – – – – 1 DRC CRC detect enabled
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 0 – – 0 0 – – Reserved
(1)
– – 0 – – – – – Disable (1-H) complementary low-pass filter generation
– – 1 – – – – – Enable (1-H) complementary low-pass filter generation
(2)(3)
– – – – – – 0 – DRC2 turned OFF
(2)
– – – – – – 1 – DRC2 turned ON
– – – – – – – 0 DRC1 turned OFF
(2)
– – – – – – – 1 DRC1 turned ON
(1) Default values are in bold.
(2) Default values are in bold.
(3) If enabled, low-pass filter is generated by (1 – high-pass filter output).
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 65
Product Folder Link(s): TAS5715