Datasheet

TAS5713
SLOS637A DECEMBER 2009REVISED AUGUST 2010
www.ti.com
Table 24. Bank Switching Command (continued)
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 EQ ON
(2)
1 EQ OFF (bypass BQ 0–7 of channels 1 and 2)
0 Reserved
(2)
0 Ignore bank-mapping in bits D31–D8.Use default mapping.
(2)
1 Use bank-mapping in bits D31–D8.
0 L and R can be written independently.
(2)
L and R are ganged for EQ biquads; a write to the left-channel
1 biquad is also written to the right-channel biquad. (0x29–0x2F is
ganged to 0x30–0x36. Also, 0x58–0x5B is ganged to 0x5C–0x5F.
0 Reserved
(2)
0 0 0 No bank switching. All updates to DAP
(2)
0 0 1 Configure bank 1 (32 kHz by default)
0 1 0 Configure bank 2 (44.1/48 kHz by default)
0 1 1 Configure bank 3 (other sample rates by default)
1 0 0 Automatic bank selection
1 0 1 Reserved
1 1 X Reserved
(2) Default values are in bold.
SPACER
REVISION HISTORY
Changes from Original (December 2009) to Revision A Page
Replaced the Dissipations Ratings Table with the Thermal Information Table .................................................................... 8
Changed Section: DEVICE PROTECTION SYSTEM ........................................................................................................ 22
Changed Section: Overcurrent (OC) Protection With Current Limiting .............................................................................. 22
Changed Section: Overcurrent (OC) Protection With Current Limiting and Overload Detection ....................................... 23
58 Submit Documentation Feedback Copyright © 2009–2010, Texas Instruments Incorporated
Product Folder Link(s): TAS5713