Datasheet
Table Of Contents
- FEATURES
- APPLICATIONS
- DESCRIPTION
- DEVICE INFORMATION
- ABSOLUTE MAXIMUM RATINGS
- THERMAL INFORMATION
- RECOMMENDED OPERATING CONDITIONS
- PWM OPERATION AT RECOMMENDED OPERATING CONDITIONS
- PLL INPUT PARAMETERS AND EXTERNAL FILTER COMPONENTS
- ELECTRICAL CHARACTERISTICS
- DC Characteristics
- AC Characteristics (BTL)
- SERIAL AUDIO PORTS SLAVE MODE
- I2C SERIAL CONTROL PORT OPERATION
- RESET TIMING (RESET)
- TYPICAL CHARACTERISTICS, BTL CONFIGURATION
- TYPICAL CHARACTERISTICS, SE CONFIGURATION
- TYPICAL CHARACTERISTICS, PBTL CONFIGURATION
- DETAILED DESCRIPTION
- POWER SUPPLY
- ERROR REPORTING
- DEVICE PROTECTION SYSTEM
- SSTIMER FUNCTIONALITY
- CLOCK, AUTO DETECTION, AND PLL
- SERIAL DATA INTERFACE
- PWM Section
- SERIAL INTERFACE CONTROL AND TIMING
- I2C SERIAL CONTROL INTERFACE
- Output Mode and MUX Selection
- 2.1-Mode Support
- Single-Filter PBTL-Mode Support
- Dynamic Range Control (DRC)
- BANK SWITCHING
- 26-Bit 3.23 Number Format
- Recommended Use Model
- CLOCK CONTROL REGISTER (0x00)
- DEVICE ID REGISTER (0x01)
- ERROR STATUS REGISTER (0x02)
- SYSTEM CONTROL REGISTER 1 (0x03)
- SERIAL DATA INTERFACE REGISTER (0x04)
- SYSTEM CONTROL REGISTER 2 (0x05)
- SOFT MUTE REGISTER (0x06)
- VOLUME REGISTERS (0x07, 0x08, 0x09, 0x0A)
- VOLUME CONFIGURATION REGISTER (0x0E)
- MODULATION LIMIT REGISTER (0x10)
- INTERCHANNEL DELAY REGISTERS (0x11, 0x12, 0x13, and 0x14)
- PWM SHUTDOWN GROUP REGISTER (0x19)
- START/STOP PERIOD REGISTER (0x1A)
- OSCILLATOR TRIM REGISTER (0x1B)
- BKND_ERR REGISTER (0x1C)
- INPUT MULTIPLEXER REGISTER (0x20)
- CHANNEL 4 SOURCE SELECT REGISTER (0x21)
- PWM OUTPUT MUX REGISTER (0x25)
- DRC CONTROL (0x46)
- BANK SWITCH AND EQ CONTROL (0x50)
- Revision History

SCLK
16Clks
LRCLK
LeftChannel
16-BitMode
1 1
15 15
14 14
MSB LSB
16Clks
RightChannel
2-ChannelI S(PhilipsFormat)StereoInput
2
T0266-01
3 3
2 2
5 5
4 4
9 98 80
13 13
10 10
11 1112 12
SCLK
MSB LSB
23
22
SCLK
32Clks
LRCLK
LeftChannel
24-BitMode
1
19 18
20-BitMode
16-BitMode
15
14
MSB LSB
32Clks
RightChannel
2-ChannelLeft-JustifiedStereoInput
T0034-02
4
5
9 8
1
4
5
1
0
0
0
23
22 1
19 18
15
14
MSB LSB
4
5
9 8
1
4
5
1
0
0
0
SCLK
TAS5711
www.ti.com
SLOS600A –DECEMBER 2009–REVISED AUGUST 2010
NOTE: All data presented in 2s-complement form with MSB first.
Figure 39. I
2
S 32-f
S
Format
Left-Justified
Left-justified (LJ) timing uses LRCLK to define when the data being transmitted is for the left channel and when it
is for the right channel. LRCLK is high for the left channel and low for the right channel. A bit clock running at 32,
48, or 64 × f
S
is used to clock in the data. The first bit of data appears on the data lines at the same time LRCLK
toggles. The data is written MSB first and is valid on the rising edge of the bit clock. The DAP masks unused
trailing data bit positions.
NOTE: All data presented in 2s-complement form with MSB first.
Figure 40. Left-Justified 64-f
S
Format
Copyright © 2009–2010, Texas Instruments Incorporated Submit Documentation Feedback 27
Product Folder Link(s): TAS5711