Datasheet
Table Of Contents
- FEATURES
- APPLICATIONS
- DESCRIPTION
- DEVICE INFORMATION
- ABSOLUTE MAXIMUM RATINGS
- THERMAL INFORMATION
- RECOMMENDED OPERATING CONDITIONS
- PWM OPERATION AT RECOMMENDED OPERATING CONDITIONS
- PLL INPUT PARAMETERS AND EXTERNAL FILTER COMPONENTS
- ELECTRICAL CHARACTERISTICS
- DC Characteristics
- AC Characteristics (BTL)
- SERIAL AUDIO PORTS SLAVE MODE
- I2C SERIAL CONTROL PORT OPERATION
- RESET TIMING (RESET)
- TYPICAL CHARACTERISTICS, BTL CONFIGURATION
- TYPICAL CHARACTERISTICS, SE CONFIGURATION
- TYPICAL CHARACTERISTICS, PBTL CONFIGURATION
- DETAILED DESCRIPTION
- POWER SUPPLY
- ERROR REPORTING
- DEVICE PROTECTION SYSTEM
- SSTIMER FUNCTIONALITY
- CLOCK, AUTO DETECTION, AND PLL
- SERIAL DATA INTERFACE
- PWM Section
- SERIAL INTERFACE CONTROL AND TIMING
- I2C SERIAL CONTROL INTERFACE
- Output Mode and MUX Selection
- 2.1-Mode Support
- Single-Filter PBTL-Mode Support
- Dynamic Range Control (DRC)
- BANK SWITCHING
- 26-Bit 3.23 Number Format
- Recommended Use Model
- CLOCK CONTROL REGISTER (0x00)
- DEVICE ID REGISTER (0x01)
- ERROR STATUS REGISTER (0x02)
- SYSTEM CONTROL REGISTER 1 (0x03)
- SERIAL DATA INTERFACE REGISTER (0x04)
- SYSTEM CONTROL REGISTER 2 (0x05)
- SOFT MUTE REGISTER (0x06)
- VOLUME REGISTERS (0x07, 0x08, 0x09, 0x0A)
- VOLUME CONFIGURATION REGISTER (0x0E)
- MODULATION LIMIT REGISTER (0x10)
- INTERCHANNEL DELAY REGISTERS (0x11, 0x12, 0x13, and 0x14)
- PWM SHUTDOWN GROUP REGISTER (0x19)
- START/STOP PERIOD REGISTER (0x1A)
- OSCILLATOR TRIM REGISTER (0x1B)
- BKND_ERR REGISTER (0x1C)
- INPUT MULTIPLEXER REGISTER (0x20)
- CHANNEL 4 SOURCE SELECT REGISTER (0x21)
- PWM OUTPUT MUX REGISTER (0x25)
- DRC CONTROL (0x46)
- BANK SWITCH AND EQ CONTROL (0x50)
- Revision History

t
w(RESET)
RESET
t
d(I2C_ready)
SystemInitialization.
EnableviaI C.
2
T0421-01
I C Active
2
I C Active
2
TAS5711
www.ti.com
SLOS600A –DECEMBER 2009–REVISED AUGUST 2010
RESET TIMING (RESET)
Control signal parameters over recommended operating conditions (unless otherwise noted). Please refer to Recommended
Use Model section on usage of all terminals.
PARAMETER MIN TYP MAX UNIT
t
w(RESET)
Pulse duration, RESET active 100 µs
t
d(I2C_ready)
Time to enable I
2
C 12.0 ms
NOTES: On power up, it is recommended that the TAS5711 RESET be held LOW for at least 100 ms after DVDD has
reached 3 V.
If the RESET is asserted LOW while PDN is LOW, then the RESET must continue to be held LOW for at least 100 ms
after PDN is deasserted (HIGH).
Figure 5. Reset Timing
Copyright © 2009–2010, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Link(s): TAS5711