Datasheet

ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
PWM OPERATION AT RECOMMENDED OPERATING CONDITIONS
TAS5710
www.ti.com
............................................................................................................................................................................................... SLOS605 JANUARY 2009
over operating free-air temperature range (unless otherwise noted)
(1) (2)
VALUE UNIT
DVDD, AVDD 0.3 to 3.6 V
Supply voltage
PVCC_X, AVCC 0.3 to 30 V
3.3-V digital inputs (except HIZ) 0.5 to DVDD + 0.5 V
3.3-V HIZ input 0.3 to AVDD + 0.3 V
Input voltage
5-V tolerant
(3)
digital inputs (except MCLK) 0.5 to DVDD + 2.5
(2)
V
5-V tolerant MCLK input 0.5 to AVDD + 2.5
(2)
V
OUT_x to PGND_X 32
(4)
V
BST_x to PGND_X 43
(4)
V
Operating free-air temperature 0 to 85 ° C
Operating junction temperature range 0 to 150 ° C
Storage temperature range, T
stg
40 to 125 ° C
(1) Stresses beyond those listed under absolute ratings may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under recommended operation conditions are
not implied. Exposure to absolute-maximum conditions for extended periods may affect device reliability.
(2) Maximum pin voltage should not exceed 6.0V
(3) 5-V tolerant inputs are PDN, RESET, SCLK, LRCLK, MCLK, SDIN, SDA, and SCL.
(4) DC voltage + peak ac waveform measured at the pin should be below the allowed limit for all conditions.
DERATING FACTOR T
A
25 ° C T
A
= 45 ° C T
A
= 70 ° C
PACKAGE
ABOVE T
A
= 25 ° C POWER RATING POWER RATING POWER RATING
7-mm × 7-mm HTQFP 40 mW/ ° C 5 W 4.2 W 3.2 W
(1) This data was taken using 1 oz trace and copper pad that is soldered directly to a JEDEC standard high-k PCB. The thermal pad must
be soldered to a thermal land on the printed-circuit board. See TI Technical Briefs SLMA002 for more information about using the
HTQFP thermal pad
MIN NOM MAX UNIT
Digital/analog supply voltage DVDD, AVDD 3 3.3 3.6 V
Half-bridge supply voltage PVCC_X, AVCC 10 26 V
V
IH
High-level input voltage Digital Inputs 2 V
V
IL
Low-level input voltage Digital Inputs 0.8 V
T
A
Operating ambient temperature range 0 85 ° C
T
J
(1)
Operating junction temperature range 0 125 ° C
R
L
(BTL) Load impedance Output filter: L = 33 µ H, C = 1 µ F. 6 8
R
L
(PBTL) Load impedance Output filter: L = 33 µ H, C = 1 µ F. 3.2 4
Minimum output inductance under 10
L
O
(BTL) Output-filter inductance µ H
short-circuit condition
Minimum output inductance under 10
L
O
(PBTL) Output-filter inductance µ H
short-circuit condition
(1) Continuous operation above the recommended junction temperature may result in reduced reliability and/or lifetime of the device.
PARAMETER TEST CONDITIONS VALUE UNIT
11.025/22.05/44.1-kHz data rate ± 2% 352.8 kHz
Output sample rate
48/24/12/8/16/32-kHz data rate ± 2% 384
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): TAS5710