Datasheet

TAS5707, TAS5707A
SLOS556B NOVEMBER 2008REVISED NOVEMBER 2009
www.ti.com
BANK SWITCH AND EQ CONTROL (0x50)
Table 23. Bank Switching Command
D31 D30 D29 D28 D27 D26 D25 D24 FUNCTION
0 32 kHz, does not use bank 3
(1)
1 32 kHz, uses bank 3
0 Reserved
(1)
0 Reserved
(1)
0 44.1/48 kHz, does not use bank 3
(1)
1 44.1/48 kHz, uses bank 3
0 16 kHz, does not use bank 3
1 16 kHz, uses bank 3
(1)
0 22.025/24 kHz, does not use bank 3
1 22.025/24 kHz, uses bank 3
(1)
0 8 kHz, does not use bank 3
1 8 kHz, uses bank 3
(1)
0 11.025 kHz/12, does not use bank 3
1 11.025/12 kHz, uses bank 3
(1)
D23 D22 D21 D20 D19 D18 D17 D16 FUNCTION
0 32 kHz, does not use bank 2
(1)
1 32 kHz, uses bank 2
1 Reserved
(1)
1 Reserved
(1)
0 44.1/48 kHz, does not use bank 2
1 44.1/48 kHz, uses bank 2
(1)
0 16 kHz, does not use bank 2
(1)
1 16 kHz, uses bank 2
0 22.025/24 kHz, does not use bank 2
(1)
1 22.025/24 kHz, uses bank 2
0 8 kHz, does not use bank 2
(1)
1 8 kHz, uses bank 2
0 11.025/12 kHz, does not use bank 2
(1)
1 11.025/12 kHz, uses bank 2
D15 D14 D13 D12 D11 D10 D9 D8 FUNCTION
0 32 kHz, does not use bank 1
1 32 kHz, uses bank 1
(1)
0 Reserved
(1)
0 Reserved
(1)
0 44.1/48 kHz, does not use bank 1
(1)
1 44.1/48 kHz, uses bank 1
0 16 kHz, does not use bank 1
(1)
1 16 kHz, uses bank 1
0 22.025/24 kHz, does not use bank 1
(1)
1 22.025/24 kHz, uses bank 1
0 8 kHz, does not use bank 1
(1)
1 8 kHz, uses bank 1
0 11.025/12 kHz, does not use bank 1
(1)
1 11.025/12 kHz, uses bank 1
(1) Default values are in bold.
48 Submit Documentation Feedback Copyright © 2008–2009, Texas Instruments Incorporated
Product Folder Link(s): TAS5707 TAS5707A