Datasheet

Protection
www.ti.com
Figure 4. TAS5518 GUI Window
From the files menu load the configuration file:
TAS5631PHD2EVM Configuration (1.00).cfg
The file is located in the EVM folder on the TI website. This file contains all settings for a default setup of
the EVM.
For easy access to the file, it is recommended that the user copy the files into the directory where the GUI
is installed. The default is C:\Program Files\Texas Instruments Inc\TAS5518\
For more advanced use of the GUI, see the GUI User’s Guide and data manual for TAS5518.
3 Protection
This section describes the short-circuit protection and fault reporting circuitry of the TAS5631 device.
3.1 Short Circuit Protection and Fault Reporting Circuitry
The TAS5631 is a self-protecting device that provides fault reporting (including high-temperature
protection and short circuit protection). TAS5631 is configured in back-end auto-recovery mode, and
resets automatically after all errors (M1, M2 and M3 is set low), see the data sheet (sles221) for further
explanation. The device will re-start itself after an error occasion, and report through the SD error signal.
3.2 Fault Reporting
The OTW and SD outputs from TAS5631 indicate fault conditions. see the TAS5631 data sheet for a
description of these pins.
8
TAS5631PHD2EVM SLOU275ADecember 2009Revised May 2010
Copyright © 2009–2010, Texas Instruments Incorporated