Datasheet

TAS5630B
www.ti.com
SLES217C NOVEMBER 2010REVISED SEPTEMBER 2012
PIN FUNCTIONS
PIN
Function
(1)
DESCRIPTION
NAME PHD NO. DKD NO.
AGND 8 10 P Analog ground
BST_A 54 43 P HS bootstrap supply (BST), external 0.033-μF capacitor to OUT_A required.
BST_B 41 34 P HS bootstrap supply (BST), external 0.033-μF capacitor to OUT_B required.
BST_C 40 33 P HS bootstrap supply (BST), external 0.033-μF capacitor to OUT_C required.
BST_D 27 24 P HS bootstrap supply (BST), external 0.033-μF capacitor to OUT_D required.
CLIP 18 O Clipping warning; open drain; active-low
C_STARTUP 3 5 O Start-up ramp requires a charging capacitor of 4.7 nF to AGND in BTL mode
FREQ_ADJ 12 14 I PWM frame-rate-programming pin requires resistor to AGND
7, 23, 24, 57,
GND 9 P Ground
58
GND_A 48, 49 38 P Power ground for half-bridge A
GND_B 46, 47 37 P Power ground for half-bridge B
GND_C 34, 35 30 P Power ground for half-bridge C
GND_D 32, 33 29 P Power ground for half-bridge D
GVDD_A 55 P Gate-drive voltage supply requires 0.1-μF capacitor to GND_A
GVDD_B 56 P Gate drive voltage supply requires 0.1-μF capacitor to GND_B
GVDD_C 25 P Gate drive voltage supply requires 0.1-μF capacitor to GND_C
GVDD_D 26 P Gate drive voltage supply requires 0.1-μF capacitor to GND_D
GVDD_AB 44 P Gate drive voltage supply requires 0.22-μF capacitor to GND_A/GND_B
GVDD_CD 23 P Gate drive voltage supply requires 0.22-μF capacitor to GND_C/GND_D
INPUT_A 4 6 I Input signal for half-bridge A
INPUT_B 5 7 I Input signal for half-bridge B
INPUT_C 10 12 I Input signal for half-bridge C
INPUT_D 11 13 I Input signal for half-bridge D
M1 20 20 I Mode selection
M2 21 21 I Mode selection
M3 22 22 I Mode selection
NC 59–62 No connect; pins may be grounded.
Analog overcurrent-programming pin requires resistor to AGND. 64-pin
OC_ADJ 1 3 O
package (PHD) = 22 kΩ. 44-pin PSOP3 (DKD) = 24 kΩ
OSC_IO+ 13 15 I/O Oscillator master/slave output/input
OSC_IO– 14 16 I/O Oscillator master/slave output/input
OTW 18 O Overtemperature warning signal, open-drain, active-low
OTW1 16 O Overtemperature warning signal, open-drain, active-low
OTW2 17 O Overtemperature warning signal, open-drain, active-low
OUT_A 52, 53 39, 40 O Output, half-bridge A
OUT_B 44, 45 36 O Output, half-bridge B
OUT_C 36, 37 31 O Output, half-bridge C
OUT_D 28, 29 27, 28 O Output, half-bridge D
PSU_REF 63 1 P PSU reference requires close decoupling of 330 pF to AGND.
Power-supply input for half-bridge A requires close decoupling of 0.01-μF
PVDD_A 50, 51 41, 42 P
capacitor in parallel with 2.2-μF capacitor to GND_A.
Power-supply input for half-bridge B requires close decoupling of 0.01-μF
PVDD_B 42, 43 35 P
capacitor in parallel with 2.2-μF capacitor to GND_B.
Power-supply input for half-bridge C requires close decoupling of 0.0- μF
PVDD_C 38, 39 32 P
capacitor in parallel with 2.2-μF capacitor to GND_C.
(1) I = Input, O = Output, P = Power
Copyright © 2010–2012, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: TAS5630B