Datasheet
TAS5548
www.ti.com
SLES270 –NOVEMBER 2012
Table 11-45. Treble and Bass Gain Step Size (Slew Rate) (continued)
D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION
0 0 1 1 1 1 1 1 Default rate - Updates every 1.31 ms (63 LRCLKs at 48 kHz). This is the
maximum constant time that can be set for all sample rates.
1 1 1 1 1 1 1 1 Maximum rate – Updates every 5.08 ms (every 255 LRCLKs at 48 kHz)
Note: Once the volume command is given, no I2C commands should be issued until volume ramp has
finished. The lock out time is 1.5 × slew rate or defined in 0xD0
Copyright © 2012, Texas Instruments Incorporated Serial-Control Interface Register Definitions 103
Submit Documentation Feedback
Product Folder Links: TAS5548