Datasheet
ERR_RCVRY
t
p(valid_low)
M-State
t
w(ER)
t
p(valid_high)
Normal
Operation
Normal
Operation
T0031-01
t
d(VOL)
VOLUME
MUTE
Normal
Operation
M-State
Normal
Operation
t
d(VOL)
T0032-01
TAS5508C
SLES257–SEPTEMBER 2010
www.ti.com
4.7.6 Back-End Error (BKND_ERR)
Control signal parameters over recommended operating conditions (unless otherwise noted)
PARAMETER MIN TYP MAX UNIT
t
w(ER)
Pulse duration, BKND_ERR active 350 None ns
t
p(valid_low)
<100 ms
t
p(valid_high)
I
2
C programmable to be between 1 to 10 ms –25 25 % of interval
Figure 4-6. Error Recovery Timing
4.7.7 Mute Timing (MUTE)
Control signal parameters over recommended operating conditions (unless otherwise noted)
PARAMETER MIN TYP MAX UNIT
t
d(VOL)
Volume ramp time Defined by rate setting
(1)
ms
(1) See the Volume Treble and Base Slew Rate Register (0xD0) , Section 7.29.
Figure 4-7. Mute Timing
60 Electrical Specifications Copyright © 2010, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TAS5508C