Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
TAS5352
SLES204A SEPTEMBER 2007 REVISED OCTOBER 2007
over operating free-air temperature range unless otherwise noted
(1)
TAS5352
VDD to AGND 0.3 V to 13.2 V
GVDD_X to AGND 0.3 V to 13.2 V
PVDD_X to GND_X
(2)
0.3 V to 53 V
OUT_X to GND_X
(2)
0.3 V to 53 V
BST_X to GND_X
(2)
0.3 V to 66.2 V
BST_X to GVDD_X
(2)
0.3 V to 53 V
VREG to AGND 0.3 V to 4.2 V
GND_X to GND 0.3 V to 0.3 V
GND_X to AGND 0.3 V to 0.3 V
GND to AGND 0.3 V to 0.3 V
PWM_X, OC_ADJ, M1, M2, M3 to AGND 0.3 V to 4.2 V
RESET_X, SD, OTW to AGND 0.3 V to 7 V
Maximum continuous sink current ( SD, OTW) 9 mA
Maximum operating junction temperature range, T
J
0 ° C to 125 ° C
Storage temperature 40 ° C to 125 ° C
Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
Minimum pulse duration, low 30 ns
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) These voltages represent the dc voltage + peak ac waveform measured at the terminal of the device in all conditions.
ORDERING INFORMATION
(1)
T
A
PACKAGE DESCRIPTION
0 ° C to 70 ° C TAS5352DDV 44-pin HTSSOP
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com .
4 Submit Documentation Feedback Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): TAS5352