Datasheet

www.ti.com
Absolute Maximum Ratings
(1)
TAS5261
SLES188 AUGUST 2006
ORDERING INFORMATION
T
A
PACKAGE DESCRIPTION
0 ° C to 70 ° C TAS5261DKD 36-pin PSOP3
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
VDD to AGND –0.3 13.2 V
GVDD_x to AGND –0.3 13.2 V
PVDD_x to PGND_x
(2)
–0.3 71 V
OUT_x to PGND_x
(2)
–0.3 71 V
BST_x to PGND_x
(2)
–0.3 79.7 V
BST_x to GVDD_x
(2)
–0.3 66.5 V
VREG to AGND –0.3 4.2 V
PGND_x to GND –0.3 0.3 V
PGND_x to AGND –0.3 0.3 V
GND to AGND –0.3 0.3 V
PWM_x, OC_ADJ, M1, M2, M3 to AGND –0.3 4.2 V
RESET, SD, OTW to AGND –0.3 7 V
Maximum continuous sink current ( SD, OTW) 9 mA
Maximum operating junction temperature range, T
J
0 150 ° C
Storage temperature range, T
stg
–65 150 ° C
Lead temperature 1,6 mm (1/16 in) from case for 10 s 260 ° C
Minimum pulse duration, low minimum pulse width must be ensured by the PWM processor 50 ns
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are only stress
ratings, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) These voltages represent the dc voltage + peak ac waveform measured at the terminal of the device in all conditions.
7