Datasheet
www.ti.com
4.13 High Current Protection (ch 1)
-8
8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
0 2m
500 m
1m 1.5m
t-Time-sec
PeakCurrent- A
4.14 High Current Protection (ch 6)
-8
8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
0 3m
500 m
1m 1.5m 2m 2.5m
t-Time-sec
PeakCurrent-
A
4.15 Pop/Click (ch 1)
TAS5176DDW6EVM Performance
Input 1 kHz bursted signal, Load 1 Ω .
Figure 16. High Current Protection (ch 1)
Input 1 kHz bursted signal, Load 1 Ω .
Figure 17. High Current Protection (ch 6)
Start of SE channels is tested for different charge times.
Charge time period is controlled by changing register x1Ah in the TAS5086.
No input signal applied, Load 8 Ω .
The measurement is done according to application note SLEA044 .
The measurement results are presented both in time domain and in frequency domain.
18 TAS5176DDW6EVM SLOU209A – September 2007 – Revised October 2007
Submit Documentation Feedback