2 Quick Setup Guide
2.1 Electrostatic Discharge Warning
2.2 Unpacking the EVM
2.3 Power Supply Setup
Quick Setup Guide
This section describes the TAS5162DKD6EVM board in regards to power supplies and system interfaces.
The section provides information regarding handling and unpacking, absolute operating conditions, and a
description of the factory default switch and jumper configuration.
This chapter provides a step-by-step guide to configuring the TAS5162DKD6EVM for device evaluation.
Many of the components on the TAS5162DKD6EVM are susceptible to damage by electrostatic discharge
(ESD). Customers are advised to observe proper ESD handling precautions when unpacking and handling
the EVM, including the use of a grounded wrist strap at an approved ESD workstation.
CAUTION
Failure to observe ESD handling procedures may result in damage to EVM
components.
Upon opening the TAS5162DKD6EVM package, check to make sure that the following items are included:
1 pc. TAS5162DKD6EVM board using one TAS5518PAG and four TAS5162DKD.
1 pc. TI Input-USB board for interfacing TAS5162DKD6EVM with SPDIF/analog sources and PC for
control.
1 pc. Signal Interface IDC cable for connection to an I
2
S front-end like the attached TI Input-USB
board.
1 pc. Control Interface IDC cable for connection to an I
2
C™ front-end like the attached TI Input-USB
board.
1 pc Cable for connecting Input-USB board to a USB port on a PC for TAS5518 control by software.
1 pc. Power supply cable for one regulated power supply (H-bridge).
1 pc. Power supply cable for two regulated power supplies (H-bridge and System supply).
1 pc. PurePath™ CD-ROM
If any of these items are missing, contact the Texas Instruments Product Information Center nearest you
to inquire about a replacement.
Connect the Input-USB board to TAS5162DKD6EVM using the 2 delivered IDC cables.
To power up the EVM, two power supplies are needed. One for system power, logic and gate-drive, and
one for output stage supply. Power supplies are connected to the EVM using delivered power cable
Red/Black, White/Black.
Table 2. Recommended Supply Voltages
Description Voltage Limitations Current Requirement Cable
System power supply 15 - 20 V 0.3 A Red/Black
Output stage power supply 0 - 50 V 10 A White/Black
CAUTION
Applying voltages above the limitations given in Table 2 may cause
permanent damage to the hardware.
SLAU223 June 2007 TAS5162DKD6EVM 5