Datasheet
www.ti.com
4.15 High Current Protection (PBTL)
PeakCurrent- A
t-Time-sec
0
500m 1.5m 2.5m1m0
-30
-10
10
-15
15
30
-5
25
2m 3m
5
-25
1.753m
20
dx=494.1 secm dy=42.25V
21.28
-20.98
1.259m
4.16 Pop/Click (BTL)
Volts-V
t-Time-sec
-40m
40m
-35m
-30m
-25m
-20m
-15m
-10m
-5m
0
5m
10m
15m
20m
25m
30m
35m
0 4m500m 1m 1.5m 2m 2.5m 3m 3.5m
TAS5162DKD6EVM Performance
Input 1 kHz bursted signal, Load 1 Ω .
Figure 18. High Current Protection (PBTL)
No input signal applied. The measurement results are presented both in time domain and in frequency
domain.
Test with automute disabled — Register x04h set to x60h. No input signal applied. Load 6 Ω .
Figure 19. Pop/Click (BTL)
SLAU223 – June 2007 TAS5162DKD6EVM 17
Submit Documentation Feedback