Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
TAS5162
SLES194D OCTOBER 2006 REVISED JULY 2007
over operating free-air temperature range unless otherwise noted
(1)
TAS5162
VDD to AGND –0.3 V to 13.2 V
GVDD_X to AGND –0.3 V to 13.2 V
PVDD_X to GND_X
(2)
–0.3 V to 71 V
OUT_X to GND_X
(2)
–0.3 V to 71V
BST_X to GND_X
(2)
–0.3 V to 79.7 V
VREG to AGND –0.3 V to 4.2 V
GND_X to GND –0.3 V to 0.3 V
GND_X to AGND –0.3 V to 0.3 V
GND to AGND –0.3 V to 0.3 V
PWM_X, OC_ADJ, M1, M2, M3 to AGND –0.3 V to 4.2 V
RESET_X, SD, OTW to AGND –0.3 V to 7 V
Maximum continuous sink current ( SD, OTW) 9 mA
Maximum operating junction temperature range, T
J
0 ° C to 125 ° C
Storage temperature –40 ° C to 125 ° C
Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
Minimum pulse duration, low 50 ns
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) These voltages represent the dc voltage + peak ac waveform measured at the terminal of the device in all conditions.
ORDERING INFORMATION
T
A
PACKAGE DESCRIPTION
0 ° C to 70 ° C TAS5162DKD 36-pin PSOP3
0 ° C to 70 ° C TAS5162DDV 44-pin HTSSOP
For the most current specification and package information, see the TI Web site at www.ti.com.
4
Submit Documentation Feedback