Datasheet
www.ti.com
SRC4382
SBFS030C – JANUARY 2006 – REVISED SEPTEMBER 2007
READYM[1:0] SRC Ready Interrupt Mode
These bits are utilized to select the active trigger state for the READY interrupt.
READYM1 READYM0 Interrupt Active State
0 0 Rising Edge Active (Default)
0 1 Falling Edge Active
1 0 Level Active
1 1 Reserved
RATIOM[1:0] SRC Ratio Interrupt Mode
These bits are utilized to select the active trigger state for the RATIO interrupt.
RATIOM1 RATIOM0 Interrupt Active State
0 0 Rising Edge Active (Default)
0 1 Falling Edge Active
1 0 Level Active
1 1 Reserved
Register 0D: Receiver Control Register 1
Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB)
0 0 0 RXBTD RXCLK 0 RXMUX1 RXMUX0
RXMUX[1:0] Receiver Input Source Selection
These bits are used to select the output of the line receiver to be used as the input data source for the DIR core.
RXMUX1 RXMUX0 Input Selection
0 0 RX1 (Default)
0 1 RX2
1 0 RX3
1 1 RX4
RXCLK Receiver Reference Clock Source
This bit is used to select the reference clock source for PLL1 in the DIR core.
RXCLK Receiver Reference Clock
0 RXCKI (Default)
1 MCLK
RXBTD Receiver C and U Data Buffer Transfer Disable
This bit is used to enable and disable buffer transfers between the Receiver Access (RA) and User Access (UA) buffers for both channel
status (C) and user (U) data.
Buffer transfers are typically disabled to allow the customer to read C and U data from the DIR UA buffer via the SPI or I
2
C serial host
interface. Once read, the RA-to-UA buffer transfer can be re-enabled to allow the RA buffer to update the contents of the UA buffer in real
time.
RXBTD Receiver Access (RA) to User Access (UA) Buffer Transfers
0 Enabled (Default)
1 Disabled; the user may read C and U data from the DIR UA buffers.
58 Submit Documentation Feedback Copyright © 2006 – 2007, Texas Instruments Incorporated
Product Folder Link(s): SRC4382