absolute maximum ratings
†
Supply voltage, V
CC
(see Note 1) −0.3 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at any bus terminal (A or B) −10 V to 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
(D, DE, R, or RE) −0.3 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge:Bus terminals and GND, Class 3, A: (see Note 2) 12 kV. . . . . . . . . . . . . . . . . . . . . . . .
Bus terminals and GND, Class 3, B: (see Note 2) 400 V. . . . . . . . . . . . . . . . . . . . . . . .
All terminals, Class 3, A: 3 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All terminals, Class 3, B: 400 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation (see Note 3) See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential I/O bus voltage, are with respect to network ground terminal.
2. Tested in accordance with MIL−STD−883C, Method 3015.7
3. The maximum operating junction temperature is internally limited. Use the dissipation rating table to operate below this temperature.
DISSIPATION RATING TABLE
PACKAGE
T
A
≤ 25°C
POWER RATING
DERATING FACTOR
‡
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
T
A
= 125°C
POWER RATING
D 725 mW 5.8 mW/°C 464 mW 377 mW 145 mW
P 1000 mW 8.0 mW/°C 640 mW 520 mW —
‡
This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with no air flow.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage, V
CC
4.75 5 5.25 V
Voltage at any bus terminal (separately or common mode), V
I
or V
IC
−7 12 V
High-level input voltage, V
IH
D, DE, and RE 2 V
CC
V
Low-level input voltage, V
IL
D, DE, and RE 0 0.8 V
Differential input voltage, V
ID
(see Note 4) −12
§
12 V
High-level output current, I
OH
Driver −60
mA
High-level output current, I
OH
Receiver −8
mA
Low-level output current, I
OL
Driver 60
mA
Low-level output current, I
OL
Receiver 8
mA
SN65LBC176AQ −40 125
Operating free-air temperature, T
A
SN65LBC176A −40 85
°C
Operating free-air temperature, T
A
SN75LBC176A 0 70
C
§
The algebraic convention, in which the least positive (most negative) limit is designated as minimum, is used in this data sheet.
NOTE 4: Differential input/output bus voltage is measured at the noninverting terminal A with respect to the inverting terminal B.