Datasheet

 
    
SLLS171G − OCTOBER 1993 − REVISED MARCH2009
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1) 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
(A or B inputs) ±25 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage, V
ID
(see Note 2) ±25 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at Y, 1/2EN, 3/4EN 0.3 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN65LBC175 −40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN75LBC175 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic Discharge (ESD): Human Body Model (HBM) 1 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Machine Model (MM) 200 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Charged Device Model (CDM) 1.5 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to GND.
2. Differential input voltage is measured at the noninverting input with respect to the corresponding inverting input.
DISSIPATION RATING TABLE
PACKAGE
T
A
25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
D 1100 mW 8.7 mW/°C 709 mW 578 mW
DW 1200 mW 9.6 mW/°C 770 mW 625 mW
N 1150 mW 9.2 mW/°C 736 mW 598 mW
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage, V
CC
4.75 5 5.25 V
Common-mode input voltage, V
IC
−7 12 V
Differential input voltage, V
ID
± 6 V
High-level input voltage, V
IH
EN inputs
2 V
Low-level input voltage, V
IL
EN inputs
0.8 V
High-level output current, I
OH
−8 mA
Low-level output current, I
OL
8 mA
Operating free-air temperature, T
A
SN65LBC175 −40 85
°C
Operating free-air temperature, T
A
SN75LBC175 0 70
°C