Datasheet

www.ti.com
Input
Generator
50
Generator: PRR = 500 kHz, 50% Duty Cycle, t
r
<6 ns, t
f
<6 ns, Z
o
= 50
V
O
1.5 V
0 V
1.5 V 1.5 V
3 V
V
OH
V
OL
1.5 V
10%
1.5 V
t
PLH
t
PHL
t
r
t
f
90%
V
I
V
O
C
L
= 15 pF ±20%
C
L
Includes Fixture
and Instrumentation
Capacitance
A
B
RE
V
I
R
0 V
90%
10%
50
Generator: PRR = 500 kHz, 50% Duty Cycle, t
r
<6 ns, t
f
<6 ns, Z
o
= 50
V
O
RE
R
A
B
3 V
0 V or 3 V
V
CC
1.5 V 1.5 V
t
PZH
t
PHZ
1.5 V
V
OH
–0.5 V
3 V
0 V
V
OH
0 V
V
O
C
L
= 15 pF ±20%
C
L
Includes Fixture
and Instrumentation
Capacitance
V
I
DE
D
1 k ± 1%
V
I
A
B
S1
D at 3 V
S1 to B
t
PZL
t
PLZ
1.5 V
V
OL
+0.5 V
V
CC
V
OL
V
O
D at 0 V
S1 to A
Input
Generator
SN75HVD08 , SN65HVD08
SLLS550C NOVEMBER 2002 REVISED JULY 2006
PARAMETER MEASUREMENT INFORMATION (continued)
Figure 6. Receiver Switching Test Circuit and Voltage Waveforms
Figure 7. Receiver Enable and Disable Time Test Circuit and Voltage Waveforms With Drivers Enabled
6