Datasheet

 
       
SLLS351E − APRIL 2002 − REVISED OCTOBER 2004
9
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
TEST CIRCUIT
50
Generator
(see Note B)
FORCEOFF
ROUT
FORCEON
Auto-
powerdown
INVALID
DOUTDIN
C
L
= 30 pF
(see Note A)
2.7 V
−2.7 V
0.3 V
−0.3 V
0 V
Valid RS-232 Level, INVALID
High
Indeterminate
Indeterminate
If Signal Remains Within This Region
For More Than 30 µs, INVALID
Is Low
Valid RS-232 Level, INVALID
High
Auto-powerdown disables drivers and reduces supply
current to 1 µA.
NOTES: A. C
L
includes probe and jig capacitance.
B. The pulse generator has the following characteristics: PRR = 5 kbit/s, Z
O
= 50 , 50% duty cycle, t
r
10 ns, t
f
10 ns.
VOLTAGE WAVEFORMS
3 V
2.7 V
−2.7 V
INVALID
Output
Receiver
Input
t
valid
0 V
0 V
−3 V
V
CC
0 V
V+
0 V
V−
V+
V
CC
t
en
V−
50% V
CC
50% V
CC
2.7 V
−2.7 V
0.3 V
0.3 V
t
invalid
Supply
Voltages
Figure 5. INVALID Propagation Delay Times and Driver Enabling Time