Datasheet

SN75976A, SN55976A
9-CHANNEL DIFFERENTIAL TRANSCEIVER
SLLS218B – MAY 1995 – REVISED MAY 1997
17
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
APPLICATION INFORMATION
Table 2. Typical Signal and Terminal Assignments
SIGNAL TERMINAL SCSI DATA SCSI CONTROL IPI DATA IPI CONTROL
CDE0 54 DIFFSENSE DIFFSENSE V
CC
V
CC
CDE1 55 GND GND XMTA, XMTB GND
CDE2 56 GND GND XMTA, XMTB SLAVE/MASTER
BSR 2 GND GND GND, BSR GND
CRE 3 GND GND GND V
CC
1A 4 DB0, DB8 ATN AD7, BD7 NOT USED
1DE/RE 5 DBE0, DBE8 INIT EN GND GND
2A 6 DB1, DB9 BSY AD6, BD6 NOT USED
2DE/RE 7 DBE1, DBE9 BSY EN GND GND
3A 8 DB2, DB10 ACK AD5, BD5 SYNC IN
3DE/RE 9 DBE2, DBE10 INIT EN GND GND
4A 10 DB3, DB11 RST AD4, BD4 SLAVE IN
4DE/RE 11 DBE3, DBE11 GND GND GND
5A 19 DB4, DB12 MSG AD3, BD3 NOT USED
5DE/RE 20 DBE4, DBE12 TARG EN GND GND
6A 21 DB5, DB13 SEL AD2, BD2 SYNC OUT
6DE/RE 22 DBE5, DBE13 SEL EN GND GND
7A 23 DB6, DB14 C/D AD1, BD1 MASTER OUT
7DE/RE 24 DBE6, DBE14 TARG EN GND GND
8A 25 DB7, DB15 REQ AD0, BD0 SELECT OUT
8DE/RE 26 DBE7, DBE15 TARG EN GND GND
9A 27 DBP0, DBP1 I/O AP, BP ATTENTION IN
9DE/RE 28 DBPE0, DBPE1 TARG EN XMTA, XMTB V
CC
ABBREVIATIONS:
DBn = data bit n, where n = (0,1, . . . ,15)
DBEn = data bit n enable, where n = (0,1, . . . ,15)
DBP0 = parity bit for data bits 0 through 7 or IPI bus A
DBPE0 = parity bit enable for P0
DBP1 = parity bit for data bits 8 through 15 or IPI bus B
DBPE1 = parity bit enable for P1
ADn or BDn = IPI Bus A – Bit n (ADn) or Bus B – Bit n (BDn), where n = (0,1, ...,7)
AP or BP = IPI parity bit for bus A or bus B
XMTA or XMTB = transmit enable for IPI bus A or B
BSR = bit significant response
INIT EN = common enable for SCSI initiator mode
TARG EN = common enable for SCSI target mode
NOTE A: Signal inputs are shown as active high. When only active-low inputs are available, logic inversion
is accomplished by reversing the B+ and B– connector terminal assignments.