Datasheet
SLRS022A − DECEMBER 1976 − REVISED OCTOBER 1995
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
SN55’ SN75’ UNIT
Supply voltage, V
CC
(see Note 1) 7 7 V
Input voltage, V
I
5.5 5.5 V
Intermitter voltage (see Note 2) 5.5 5.5 V
Off-state output voltage, V
O
35 35 V
Continuous collector or output current (see Note 3) 400 400 mA
Peak collector or output current (t
w
≤ 10 ms, duty cycle ≤ 50%, see Note 4)
500
500
mA
Peak collector or output current (t
w
≤ 10 ms, duty cycle ≤ 50%, see Note 4) 500 500 mA
Continuous total power dissipation See Dissipation Rating Table
Operating free-air temperature range, T
A
−55 to 125 0 to 70 °C
Storage temperature range, T
stg
−65 to 150 −65 to 150 °C
Case temperature for 60 seconds, T
C
FK package 260 °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds JG package 300 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or P package 260 °C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Voltage values are with respect to network GND unless otherwise specified.
2. This is the voltage between two emitters A and B.
3. This value applies when the base-emitter resistance (R
BE
) is equal to or less than 500 Ω.
4. Both halves of these dual circuits may conduct rated current simultaneously; however, power dissipation averaged over a short time
interval must fall within the continuous dissipation rating.
DISSIPATION RATING TABLE
PACKAGE
T
A
≤
25
°
C
DERATING FACTOR
T
A
= 70
°
C
T
A
= 125
°
C
PACKAGE
T
A
≤ 25 C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70 C
POWER RATING
T
A
= 125 C
POWER RATING
D 725 mW 5.8 mW/°C 464 mW −
FK 1375 mW 11.0 mW/°C 880 mW 275 mW
JG 1050 mW 8.4 mW/°C 672 mW 210 mW
P 1000 mW 8.0 mW/°C 640 mW −
recommended operating conditions
SN55’ SN75’
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
Supply voltage, V
CC
4.5 5 5.5 4.75 5 5.25 V
High-level input voltage, V
IH
2 2 V
Low-level input voltage, V
IL
0.8 0.8 V
Operating free-air temperature, T
A
−55 125 0 70 °C