Datasheet


  
SLRS028A − SEPTEMBER 1988 − REVISED NOVEMBER 2004
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
schematic (each driver)
To Other Drivers
Enable E1
Enable E2
Input A
V
CC1
V
CC3
V
CC2
Output Y
GND
To Other Drivers
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range (see Note 1):V
CC1
0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC2
0.5 V to 25 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC3
0.5 V to 30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
5.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak output current, I
I
(t
w
< 10 ms, duty cycle < 50%) 500 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Notes 2 and 3): D package 73°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . .
N package 67°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Voltage values are with respect to network ground terminal.
2. Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
MIN NOM MAX
UNIT
V
CC1
Supply voltage 4.75 5 5.25 V
V
CC2
Supply voltage 4.75 20 24 V
V
CC3
Supply voltage V
CC2
24 28 V
V
CC3
− V
CC2
Voltage difference between supply voltages 0 4 10 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
OH
High-level output current −10 mA
I
OL
Low-level output current 40 mA
T
A
Operating free-air temperature 0 70 °C