Datasheet

SN75154
QUADRUPLE LINE RECEIVER
SLLS083B – NOVEMBER 1970 – REVISED MAY 1995
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST
TEST CONDITIONS
MIN
TYP
MAX
PARAMETER
FIGURE
TEST
CONDITIONS
MIN
TYP
MAX
V
IT
Positive-going input
Normal operation
1
0.8 2.2 3
V
IT+
gg
threshold voltage
Fail-safe operation
1
0.8 2.2 3
V
IT
Negative-going input
Normal operation
1
–3 1.1 0
V
IT–
ggg
threshold voltage
Fail-safe operation
1
0.8 1.4 3
V
h
Hysteresis voltage
Normal operation
1
0.8 3.3 6
V
hys
yg
(V
IT+
– V
IT–
)
Fail-safe operation
1
0 0.8 2.2
V
OH
High-level output voltage 1 I
OH
= –400 µA 2.4 3.5 V
V
OL
Low-level output voltage 1 I
OL
= 16 mA 0.29 0.4 V
V
I
= –25 V to –14 V 3 5 7
V
I
= –14 V to –3 V 3 5 7
r
i
Input resistance 2
V
I
= –3 V to 3 V 3 6 8
V
I
= 3 V to 14 V 3 5 7
V
I
= 14 V to 25 V 3 5 7
V
I(open)
Open-circuit input voltage 3 I
I
= 0 0 0.2 2 V
I
OS
Short-circuit output current
4 V
CC1
= 5.5 V, V
I
= –5 V –10 –20 –40 mA
I
CC1
Supply current from V
CC1
5
V
CC1
= 5.5 V, T
A
= 25°C 20 35
I
CC2
Supply current from V
CC2
5
V
CC2
= 13.2 V, T
A
= 25°C 23 40
All typical values are at V
CC1
= 5 V, T
A
= 25°C.
Not more than one output should be shorted at a time.
switching characteristics, V
CC1
= 5 V, T
A
= 25°C, N = 10
PARAMETER
TEST
TEST CONDITIONS
MIN
TYP
MAX
PARAMETER
FIGURE
TEST
CONDITIONS
MIN
TYP
MAX
t
PLH
Propagation delay time, low- to high-level output 11 ns
t
PHL
Propagation delay time, high- to low-level output
6
C
L
=50
p
FR
L
= 390
8 ns
t
TLH
Transition time, low- to high-level output
6
C
L
=
50
pF
,
R
L
=
390
7 ns
t
THL
Transition time, high- to low-level output 2.2 ns