Datasheet
SN55116, SN75116, SN75117, SN75118, SN75119
DIFFERENTIAL LINE TRANSCEIVERS
SLLS073D − MAY 1976 − REVISED MAY 1998
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
switching characteristics, V
CC
= 5 V, C
L
= 30 pF, T
A
= 25°C
driver section
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
PLH
Propagation-delay time, low-to-high level output
See Figure 13
14 30
ns
t
PHL
Propagation-delay time, high-to-low level output
See Figure 13
12 30
ns
t
PZH
Output-enable time to high level R
L
= 180 Ω, See Figure 14 8 20 ns
t
PZL
Output-enable time to low level R
L
= 250 Ω, See Figure 15 17 40 ns
t
PHZ
Output-disable time from high level R
L
= 180 Ω, See Figure 14 16 30 ns
t
PLZ
Output-disable time from low level R
L
= 250 Ω, See Figure 15 20 35 ns