Datasheet
SN55116, SN75116, SN75117, SN75118, SN75119
DIFFERENTIAL LINE TRANSCEIVERS
SLLS073D − MAY 1976 − REVISED MAY 1998
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
•
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
driver section
PARAMETER
TEST CONDITIONS
†
’116, SN75118 SN75117, SN75119
UNIT
PARAMETER
TEST CONDITIONS
†
MIN
TYP
‡
MAX MIN TYP
‡
MAX
UNIT
V
IK
Input clamp voltage V
CC
= MIN, I
I
= −12 mA −0.9 −1.5 −0.9 −1.5 V
T
A
= 25°C (SN55116),
T
A
= 0°C to 70°C
I
OH
= −10 mA 2.4 3.4 2.4 3.4
V
OH
High-level output voltage
V
CC
= MIN,
V
IL
= 0.8 V,
I 2V
T
A
=
0 C
to
70 C
(SN75116, SN75117,
SN75118, SN75119)
I
OH
= −40 mA 2 3 2 3
V
I
IH
= 2 V
T
A
= −55°C to 125°C
I
OH
= −10 mA 2 2
T
A
=
−
55 C
to
125 C
(SN55116)
I
OH
= −40 mA 1.8 1.8
V
OL
Low-level output voltage V
CC
= MIN, V
IH
= 2 V, V
IL
= 0.8 V, I
OL
= 40 mA 0.4 0.4 V
V
OK
Output clamp voltage V
CC
= MAX, I
O
= −40 mA, DE at 0.8 V −1.5 −1.5 V
T
A
= 25°C 1 10
I
O(off)
Off
-
state open
-
collector output current
V
CC
= MAX, SN55116 200
µA
I
O(off)
Off
-s
t
a
t
e open-co
ll
ec
t
or ou
t
pu
t
curren
t
CC
,
V
O
= 12 V
T
A
= MAX
SN75116,
SN75118
20
µ
A
V
CC
= MAX, V
O
= 0 to V
CC,
DE at 0.8 V, T
A
= 25°C ± 10
Off state (high impedance state)
V MAX
V
O
= 0 SN55116 −300
I
OZ
Off-state (high-impedance-state)
out
p
ut current
V
CC
= MAX,
DEat08V
V
O
= 0.4 V to V
CC
SN55116 ±150
µA
OZ
output
current
DE
a
t
0
.
8
V
,
T
A
= MAX
V
O
= 0 to V
CC
SN75116,
SN75118
± 20
µ
I
Input current at maximum
V = MAX
V =55V
1
1
mA
I
I
Input
current
at
maximum
input voltage
Driver or
V
CC
= MAX, V
I
= 5.5 V 1 1mA
I
IH
High-level input current
Driver
or
enable input
V
CC
= MAX, V
I
= 2.4 V 40 40 µA
I
IL
Low-level input current
enable
input
V
CC
= MAX, V
I
= 0.4 V −1.6 −1.6 mA
I
OS
Short-circuit output current
§
V
CC
= MAX, V
O
= 0, T
A
= 25°C −40 −120 −40 −120 mA
I
Supply current (driver and receiver
V = MAX
T =25°C
42
60
42
60
mA
I
CC
Supply
current
(driver
and
receiver
combined)
V
CC
= MAX, T
A
= 25°C 42 60 42 60 mA
†
All parameters with the exception of off-state open-collector output current are measured with the active pullup connected to the sink output. For conditions shown as MIN or MAX,
use the appropriate value specified under recommended operating conditions.
‡
All typical values are at V
CC
= 5 V and T
A
= 25°C.
§
Not more than one output should be shorted at a time, and duration of the short circuit should not exceed one second.