Datasheet
SN55115, SN75115
DUAL DIFFERENTIAL RECEIVERS
SLLS072D – SEPTEMBER 1973 – REVISED MAY 1998
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
†
SN55115 SN75115
UNIT
PARAMETER
TEST
CONDITIONS
†
MIN TYP
‡
MAX MIN TYP
‡
MAX
UNIT
V
IT+
§
Positive-going
threshold voltage
V
O
= 0 .4 V, I
OL
= 15 mA, V
IC
= 0 500 500 mV
V
IT–
§
Negative-going
threshold voltage
V
O
= 2 .4 V, I
OH
= –5 mA, V
IC
= 0
–500
¶
–500
¶
mV
V
ICR
Common-mode
input voltage range
V
ID
= ±1 V
+15
to
–15
+24
to
–19
+15
to
–15
+24
to
–19
V
Hi h l l t
V MIN
V05V
T
A
= MIN 2.2 2.4
V
OH
High-level ouput
voltage
V
CC
= MIN,
I
OH
=
–
5mA
V
ID
= –0.5 V,
T
A
= 25°C
2.4 3.4 2.4 3.4
V
voltage
I
OH
=
–
5
mA
T
A
= MAX 2.4 2.4
V
OL
Low-level output
voltage
V
CC
= MIN,
I
OL
= 15 mA
V
ID
= –0.5 V,
0.22 0.4 0.22 0.45 V
Lllit
V MAX V 0 4 V
T
A
= MIN –0.9 –0.9
I
IL
Low-level input
current
V
CC
= MAX, V
I
= 0.4 V,
Other in
p
ut at 5 5 V
T
A
= 25°C –0.5 –0.7 –0.5 –0.7
mA
current
Other
in ut
at
5
.
5
V
T
A
= MAX –0.7 –0.7
I
SH
High-level strobe V
CC
= MIN, V
ID
= –0.5 V,
T
A
= 25°C 2 5
µA
I
SH
g
current
CC
,
V
strobe
= 4.5 V
ID
,
T
A
= MAX 5 10
µ
A
I
SL
Low-level strobe
current
V
CC
= MAX,
V
strobe
= 0.4 V
V
ID
= 0.5 V,
T
A
= 25°C –1.15 –2.4 –1.15 –2.4 mA
I(
RTC)
Response-time-
control current
V
CC
= MAX,
V
RC
= 0
V
ID
= 0.5 V,
T
A
= 25°C –1.2 –3.4 –1.2 –3.4 mA
V
CC
= MIN, V
OH
= 12 V,
T
A
= 25°C 100
I
O
(off)
Off-state
o
p
en collector
CC
,
V
ID
= –4.5 V
OH
,
T
A
= MAX 200
µA
I
O
(off)
open-co
ll
ec
t
or
o
u
tp
u
t
cu
rr
e
nt
V
CC
= MIN, V
OH
= 5.25 V,
T
A
= 25°C 100
µ
A
out ut
current
CC
,
V
ID
= –4.75 V
OH
,
T
A
= MAX 200
R
T
Line-terminating
resistance
V
CC
= 5 V T
A
= 25°C 77 130 167 74 130 179 Ω
I
OS
Supply-circuit output
current
#
V
CC
= MAX,
V
O
= 0
V
ID
= –0.5 V,
T
A
= 25°C –15 –40 –80 –14 –40 –100 mA
I
CC
Supply current
(both receivers)
V
CC
= MAX,
V
IC
= 0
V
ID
= 0.5 V,
T
A
= 25°C 32 50 32 50 mA
†
Unless otherwise noted, V
strobe
= 2.4 V. All parameters with the exception of off-state open-collector output current are measured with the active
pullup connected to the sink output.
‡
All typical values are at V
CC
= 5 V, T
A
= 25°C, and V
IC
= 0.
§
Differential voltages are at the B input terminal with respect to the A input terminal.
¶
The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold
voltages only.
#
Only one output should be shorted to ground at a time, and duration of the short circuit should not exceed one second.