Datasheet
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C − SEPTEMBER 1973 − REVISED MARCH 1997
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
recommended operating conditions
SN55113 SN75113
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
Supply voltage, V
CC
4.5 5 5.5 4.75 5 5.25 V
High-level input voltage, V
IH
2 2 V
Low-level input voltage, V
IL
0.8 0.8 V
High-level output current, I
OH
− 40 − 40 mA
Low-level output current, I
OL
40 40 mA
Operating free-air temperature, T
A
−55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
†
SN55113 SN75113
UNIT
PARAMETER
TEST CONDITIONS
†
MIN TYP
‡
MAX MIN TYP
‡
MAX
UNIT
V
IK
Input clamp voltage V
CC
= MIN, I
I
= −12 mA −0.9 −1.5 −0.9 −1.5 V
V
Hi
g
h-level output V
CC
= MIN, V
IH
= 2 V,
I
OH
= −10 mA 2.4 3.4 2.4 3.4
V
V
OH
High level
output
voltage
V
CC
=
MIN
,
V
IL
= 0.8 V
V
IH
=
2
V
,
I
OH
= −40 mA 2 3.0 2 3.0
V
V
Low-level output V
CC
= MIN, V
IH
= 2 V,
V
IL
= 0.8 V
,
023
04
023
04
V
V
OL
Low level
output
voltage
V
CC
=
MIN
,
I
OL
= 40 mA
V
IH
=
2
V
,
V
IL
=
0
.
8
V
,
0.23 0.4 0.23 0.4 V
V
OK
Output clamp voltage V
CC
= MAX, I
O
= − 40 mA −1.1 −1.5 −1.1 −1.5 V
V 12 V
T
A
= 25°C 1 10
I
Off-state
open collector output
V MAX
V
OH
= 12 V
T
A
= 125°C 200
A
I
O(off)
open-collector output
cu
rr
e
nt
V
CC
= MAX
V 525V
T
A
= 25°C 1 10
μA
current
V
OH
= 5.25 V
T
A
= 70°C 20
T
A
= 25°C, V
O
= 0 to V
CC
± 10 ± 10
Off
-
state
V
CC
= MAX,
O
V
O
= 0 −150 −20
I
OZ
Off
-
state
(high-impedance-state)
CC
Output
controls at
T MAX
V
O
= 0.4 V ± 80 ± 20
μA
I
OZ
(high impedance state)
output current
con
t
ro
l
s a
t
0.8 V
T
A
= MAX
V
O
= 2.4 V ± 80 ± 20
μA
0
.
8
V
V
O
= V
CC
80 20
I
Input current
at maximum
A, B, C
V MAX
V 55V
1 1
mA
I
I
at maximum
input voltage
CC
V
CC
= MAX, V
I
= 5.5 V
2 2
mA
I
Hi
g
h-level
A, B, C
V MAX
V 24V
40 40
A
I
IH
High level
input current
CC
V
CC
= MAX, V
I
= 2.4 V
80 80
μA
I
Low-level
A, B, C
V MAX
V 04V
−1.6 −1.6
mA
I
IL
Low level
input current
CC
V
CC
= MAX, V
I
= 0.4 V
−3.2 −3.2
mA
I
Short-circuit
V MAX
V 0
T 25°C
40
90
120
40
90
120
mA
I
OS
Short circuit
output current
§
V
CC
= MAX, V
O
= 0, T
A
= 25°C−40−90 −120 −40 −90 −120 mA
I
Suppl
y
current All inputs at 0 V, No load,
V
CC
= MAX 47 65 47 65
mA
I
CC
Supply
current
(both drivers)
All
inputs
at
0
V
,
No
load
,
T
A
= 25°C
V
CC
= 7 V 65 85 65 85
mA
†
All parameters with the exception of off-state open-collector output current are measured with the active pullup connected to the sink output. For
conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡
All typical values are at T
A
= 25°C and V
CC
= 5 V, with the exception of V
CC
at 7 V.
§
Only one output should be shorted at a time, and duration of the short-circuit should not exceed one second.