Datasheet

SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C − SEPTEMBER 1973 − REVISED MARCH 1997
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
SN55113 SN75113
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
Supply voltage, V
CC
4.5 5 5.5 4.75 5 5.25 V
High-level input voltage, V
IH
2 2 V
Low-level input voltage, V
IL
0.8 0.8 V
High-level output current, I
OH
− 40 − 40 mA
Low-level output current, I
OL
40 40 mA
Operating free-air temperature, T
A
−55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN55113 SN75113
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
V
IK
Input clamp voltage V
CC
= MIN, I
I
= −12 mA 0.9 1.5 0.9 1.5 V
V
Hi
g
h-level output V
= MIN, V
IH
= 2 V,
I
OH
= −10 mA 2.4 3.4 2.4 3.4
V
V
OH
High level
output
voltage
,
V
IL
= 0.8 V
V
IH
=
2
V
,
I
OH
= −40 mA 2 3.0 2 3.0
V
V
Low-level output V
= MIN, V
IH
= 2 V,
V
= 0.8 V
023
04
023
04
V
V
OL
Low level
output
voltage
,
I
OL
= 40 mA
V
IH
=
2
V
,
.
,
0.23 0.4 0.23 0.4 V
V
OK
Output clamp voltage V
CC
= MAX, I
O
= − 40 mA −1.1 −1.5 −1.1 −1.5 V
V 12 V
T
A
= 25°C 1 10
I
Off-state
open collector output
V
OH
= 12 V
T
A
= 125°C 200
A
I
O(off)
open-collector output
cu
rr
e
nt
V
CC
= MAX
V 525V
T
A
= 25°C 1 10
μA
current
V
OH
= 5.25 V
T
A
= 70°C 20
T
A
= 25°C, V
O
= 0 to V
CC
± 10 ± 10
Off
-
state
V
CC
= MAX,
V
O
= 0 150 −20
I
OZ
Off
-
state
(high-impedance-state)
Output
T MAX
V
O
= 0.4 V ± 80 ± 20
μA
I
OZ
(high impedance state)
output current
con
ro
s a
0.8 V
T
A
= MAX
V
O
= 2.4 V ± 80 ± 20
μA
.
V
O
= V
CC
80 20
I
Input current
at maximum
A, B, C
V 55V
1 1
mA
I
I
at maximum
input voltage
CC
V
CC
= MAX, V
I
= 5.5 V
2 2
mA
I
Hi
g
h-level
A, B, C
V 24V
40 40
A
I
IH
High level
input current
CC
V
CC
= MAX, V
I
= 2.4 V
80 80
μA
I
Low-level
A, B, C
V 04V
1.6 1.6
mA
I
IL
Low level
input current
CC
V
CC
= MAX, V
I
= 0.4 V
3.2 3.2
mA
I
Short-circuit
V 0
40
90
120
40
90
120
mA
I
OS
Short circuit
output current
§
V
CC
= MAX, V
O
= 0, T
A
= 25°C−40−90 −120 −40 90 120 mA
I
Suppl
y
current All inputs at 0 V, No load,
V
CC
= MAX 47 65 47 65
mA
I
CC
Supply
current
(both drivers)
All
inputs
at
0
V
,
No
load
,
T
A
= 25°C
V
CC
= 7 V 65 85 65 85
mA
All parameters with the exception of off-state open-collector output current are measured with the active pullup connected to the sink output. For
conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
All typical values are at T
A
= 25°C and V
CC
= 5 V, with the exception of V
CC
at 7 V.
§
Only one output should be shorted at a time, and duration of the short-circuit should not exceed one second.