Datasheet

www.ti.com
AC Performance (Translating Down)
Switching Characteristics
Switching Characteristics
AC Performance (Translating Up)
Switching Characteristics
Switching Characteristics
SN74TVC3306
DUAL VOLTAGE CLAMP
SCDS112C MARCH 2001 REVISED MARCH 2005
over recommended operating free-air temperature range, V
GATE
= 3.3 V, V
IH
= 3.3 V, V
IL
= 0, and V
M
= 1.15 V
(unless otherwise noted) (see Figure 1 )
C
L
= 50 pF C
L
= 30 pF C
L
= 15 pF
FROM TO
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX
t
PLH
0 0.8 0 0.6 0 0.3
A or B B or A ns
t
PHL
0 1.2 0 1 0 0.5
over recommended operating free-air temperature range, V
GATE
= 2.5 V, V
IH
= 2.5 V, V
IL
= 0, and V
M
= 0.75 V
(unless otherwise noted) (see Figure 1 )
C
L
= 50 pF C
L
= 30 pF C
L
= 15 pF
FROM TO
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX
t
PLH
0 1 0 0.7 0 0.4
A or B B or A ns
t
PHL
0 1.3 0 1 0 0.6
over recommended operating free-air temperature range, V
GATE
= 3.3 V, V
IH
= 2.3 V, V
IL
= 0, V
T
= 3.3 V, V
M
= 1.15 V, and
R
L
= 300 (unless otherwise noted) (see Figure 1 )
C
L
= 50 pF C
L
= 30 pF C
L
= 15 pF
FROM TO
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX
t
PLH
0 0.9 0 0.6 0 0.4
A or B B or A ns
t
PHL
0 1.4 0 1.1 0 0.7
over recommended operating free-air temperature range, V
GATE
= 2.5 V, V
IH
= 1.5 V, V
IL
= 0, V
T
= 2.5 V, V
M
= 0.75 V, and
R
L
= 300 (unless otherwise noted) (see Figure 1 )
C
L
= 50 pF C
L
= 30 pF C
L
= 15 pF
FROM TO
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX
t
PLH
0 1 0 0.6 0 0.4
A or B B or A ns
t
PHL
0 1.3 0 1.3 0 0.8
3