Datasheet


  
SCDS087G − APRIL 1999 − REVISED APRIL 2005
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
MAX UNIT
V
IK
V
BIAS
= 0, I
I
= −18 mA −1.2 V
V
OL
I
REF
= 5 mA,
V
DPU
= 2.625 V,
V
REF
= 1.365 V,
R
DPU
= 150
V
S
= 0.175 V,
See Figure 2
350 mV
C
i(GATE)
V
I
= 3 V or 0 73 pF
C
io(off)
V
O
= 3 V or 0 4 12 pF
C
io(on)
V
O
= 3 V or 0 12 25 pF
r
on
I
REF
= 5 mA,
V
DPU
= 2.625 V,
V
REF
= 1.365 V,
R
DPU
= 150
V
S
= 0.175 V,
See Figure 2
12.5
All typical values are at T
A
= 25°C.
Measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by
the lower voltage of the two (A or B) terminals.
electrical characteristics from −40°C to 75°C
PARAMETER TEST CONDITIONS MIN MAX UNIT
r
on
I
REF
= 5 mA,
V
DPU
= 2.625 V,
V
REF
= 1.552 V,
R
DPU
= 150
V
S
= 0.175 V,
See Figure 2
10
Measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by
the lower voltage of the two (A or B) terminals.
switching characteristics over recommended operating free-air temperature range,
V
DPU
= 2.36 V to 2.64 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN MAX UNIT
t
PLH
A or B
B or A
0 4
ns
t
PHL
A or B B or A
0 4
ns