Datasheet
www.ti.com
Recommended Operating Conditions
(1)
Electrical Characteristics
SN54LVTH162244 , , SN74LVTH162244
3.3-V ABT 16-BIT BUFFERS/DRIVERS
WITH 3-STATE OUTPUTS
SCBS258N – JUNE 1993 – REVISED NOVEMBER 2006
SN54LVTH162244 SN74LVTH162244
UNIT
MIN MAX MIN MAX
V
CC
Supply voltage 2.7 3.6 2.7 3.6 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
V
I
Input voltage 5.5 5.5 V
I
OH
High-level output current –12 –12 mA
I
OL
Low-level output current 12 12 mA
∆ t/ ∆ v Input transition rise or fall rate Outputs enabled 10 10 ns/V
∆ t/ ∆ V
CC
Power-up ramp rate 200 200 µ s/V
T
A
Operating free-air temperature –55 125 –40 85 ° C
(1) All unused control inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
over recommended operating free-air temperature range (unless otherwise noted)
SN54LVTH162244 SN74LVTH162244
PARAMETER TEST CONDITIONS UNIT
MIN TYP
(1)
MAX MIN TYP
(1)
MAX
V
IK
V
CC
= 2.7 V, I
I
= –18 mA –1.2 –1.2 V
V
OH
V
CC
= 3 V, I
OH
= –12 mA 2 2 V
V
OL
V
CC
= 3 V, I
OL
= 12 mA 0.8 0.8 V
V
CC
= 0 or 3.6 V, V
I
= 5.5 V 10 10
Control
V
CC
= 3.6 V, V
I
= V
CC
or GND ± 1 ± 1
inputs
I
I
µ A
V
I
= V
CC
1 1
Data inputs V
CC
= 3.6 V
V
I
= 0 –5 –5
I
off
V
CC
= 0, V
I
or V
O
= 0 to 4.5 V ± 100 µ A
V
I
= 0.8 V 75 75
V
CC
= 3 V
V
I
= 2 V –75 –75
I
I(hold)
Data inputs µ A
500
V
CC
= 3.6 V,
(2)
V
I
= 0 to 3.6 V
–750
I
OZH
V
CC
= 3.6 V, V
O
= 3 V 5 5 µ A
I
OZL
V
CC
= 3.6 V, V
O
= 0.5 V –5 –5 µ A
I
OZPU
V
CC
= 0 to 1.5 V, V
O
= 0.5 V to 3 V, OE = don't care ± 100
(3)
± 100 µ A
I
OZPD
V
CC
= 1.5 V to 0, V
O
= 0.5 V to 3 V, OE = don't care ± 100
(3)
± 100 µ A
Outputs high 0.19 0.19
V
CC
= 3.6 V,
I
CC
I
O
= 0, Outputs low 5 5 mA
V
I
= V
CC
or GND
Outputs disabled 0.19 0.19
V
CC
= 3 V to 3.6 V, One input at V
CC
– 0.6 V,
∆ I
CC
(4)
0.2 0.2 mA
Other inputs at V
CC
or GND
C
i
V
I
= 3 V or 0 4 4 pF
C
o
V
O
= 3 V or 0 9 9 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25 ° C.
(2) This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
(3) On products compliant to MIL-PRF-38535, this parameter is not production tested.
(4) This is the increase in supply current for each input that is at the specified TTL voltage level, rather than V
CC
or GND.
5