Datasheet


   
  
SCBS134K − SEPTEMBER 1992 − REVISED JANUARY 2004
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 3.3 V
± 0.3 V
V
CC
= 2.7 V
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN TYP
MAX MIN MAX
UNIT
t
PLH
A
Y
1.1 2.2 3.8 4.6
ns
t
PHL
A Y
1.3 2.6 4 4.2
ns
t
PZH
OE
Y
1.1 2.6 4.6 5.6
ns
t
PZL
OE
Y
1.4 2.7 4.4 5
ns
t
PHZ
OE
Y
2 2.9 4.4 4.6
ns
t
PLZ
OE
Y
1.8 3 4.3 4.3
ns
All typical values are at V
CC
= 3.3 V, T
A
= 25°C.