Datasheet
www.ti.com
Electrical Characteristics
SN74LVCHR16245A
16-BIT BUS TRANSCEIVER
WITH 3-STATE OUTPUTS
SCAS582P – NOVEMBER 1996 – REVISED DECEMBER 2005
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP
(1)
MAX UNIT
I
OH
= –100 µ A 1.65 V to 3.6 V V
CC
– 0.2
I
OH
= –2 mA 1.65 V 1.2
2.3 V 1.7
I
OH
= –4 mA
V
OH
2.7 V 2.2 V
I
OH
= –6 mA 3 V 2.4
I
OH
= –8 mA 2.7 V 2
I
OH
= –12 mA 3 V 2
I
OL
= 100 µ A 1.65 V to 3.6 V 0.2
I
OL
= 2 mA 1.65 V 0.45
2.3 V 0.7
I
OL
= 4 mA
V
OL
2.7 V 0.4 V
I
OL
= 6 mA 3 V 0.55
I
OL
= 8 mA 2.7 V 0.6
I
OL
= 12 mA 3 V 0.8
I
I
Control inputs V
I
= 0 to 5.5 V 3.6 V ±5 µ A
V
I
= 0.58 V
(2)
1.65 V
V
I
= 1.07 V
(2)
V
I
= 0.7 V 45
2.3 V
I
I(hold)
A or B port V
I
= 1.7 V –45 µ A
V
I
= 0.8 V 75
3 V
V
I
= 2 V –75
V
I
= 0 to 3.6 V
(3)
3.6 V ±500
I
off
V
I
or V
O
= 5.5 V 0 ±10 µ A
I
OZ
(4)
V
O
= 0 V or (V
CC
to 5.5 V) 2.3 V to 3.6 V ±5 µ A
V
I
= V
CC
or GND 20
I
CC
I
O
= 0 3.6 V µ A
3.6 V ≤ V
I
≤ 5.5 V
(5)
20
∆ I
CC
One input at V
CC
– 0.6 V, Other inputs at V
CC
or GND 2.7 V to 3.6 V 500 µ A
C
i
Control inputs V
I
= V
CC
or GND 3.3 V 3 pF
C
io
A or B port V
O
= V
CC
or GND 3.3 V 12 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
(2) This information was not available at the time of publication.
(3) This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
(4) For the total leakage current in an I/O port, please consult the I
I(hold)
specification for the input voltage condition 0 V < V
I
< V
CC
, and the
I
OZ
specification for the input voltage conditions V
I
= 0 V or V
I
= V
CC
to 5.5 V. The bus-hold current, at input voltages greater than V
CC
,
is negligible.
(5) This applies in the disabled state only.