Datasheet
www.ti.com
Electrical Characteristics
SN54LVCH245A, SN74LVCH245A
OCTAL BUS TRANSCEIVERS
WITH 3-STATE OUTPUTS
SCES008O – JULY 1995 – REVISED DECEMBER 2005
over recommended operating free-air temperature range (unless otherwise noted)
SN54LVCH245A SN74LVCH245A
PARAMETER TEST CONDITIONS V
CC
UNIT
MIN TYP
(1)
MAX MIN TYP
(1)
MAX
V
CC
1.65 V to 3.6 V
– 0.2
I
OH
= –100 µ A
V
CC
2.7 V to 3.6 V
– 0.2
I
OH
= –4 mA 1.65 V 1.2
V
OH
V
I
OH
= –8 mA 2.3 V 1.7
2.7 V 2.2 2.2
I
OH
= –12 mA
3 V 2.4 2.4
I
OH
= –24 mA 3 V 2.2 2.2
1.65 V to 3.6 V 0.2
I
OL
= 100 µ A
2.7 V to 3.6 V 0.2
I
OL
= 4 mA 1.65 V 0.45
V
OL
V
I
OL
= 8 mA 2.3 V 0.7
I
OL
= 12 mA 2.7 V 0.4 0.4
I
OL
= 24 mA 3 V 0.55 0.55
I
I
Control inputs V
I
= 0 to 5.5 V 3.6 V ± 5 ± 5 µ A
I
off
V
I
or V
O
= 5.5 V 0 ± 10 µ A
V
I
= 0.58 V 25
1.65 V
V
I
= 1.07 V –25
V
I
= 0.7 V 45
2.3 V
I
I(hold)
V
I
= 1.7 V –45 µ A
V
I
= 0.8 V 75 75
3 V
V
I
= 2 V –75 –75
V
I
= 0 to 3.6 V
(2)
3.6 V ± 500 ± 500
I
OZ
(3)
V
O
= 0 V or (V
CC
to 5.5 V) 2.3 V to 3.6 V ± 15 ± 5 µ A
V
I
= V
CC
or GND 10 10
I
CC
I
O
= 0 3.6 V µ A
3.6 V ≤ V
I
≤ 5.5 V
(4)
10 10
One input at V
CC
– 0.6 V,
∆ I
CC
2.7 V to 3.6 V 500 500 µ A
Other inputs at V
CC
or GND
C
i
Control inputs V
I
= V
CC
or GND 3.3 V 4 12 4 pF
C
io
A or B port V
O
= V
CC
or GND 3.3 V 5.5 12 5.5 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25 ° C.
(2) This is the bus-hold maximum dynamic current required to switch the input from one state to another.
(3) For the total leakage current in an I/O port, please consult the I
I(hold)
specification for the input voltage condition 0 V < V
I
< V
CC
, and the
I
OZ
specification for the input voltage conditions V
I
= 0 V or V
I
= V
CC
to 5.5 V. The bus-hold current, at input voltage greater than V
CC
, is
negligible.
(4) This applies in the disabled state only.
5