Datasheet
SN74LVC2T45-EP
SCES777C –NOVEMBER 2008–REVISED JULY 2010
www.ti.com
Power-Up Considerations
A proper power-up sequence always should be followed to avoid excessive supply current, bus contention,
oscillations, or other anomalies. To guard against such power-up problems, take the following precautions:
1. Connect ground before any supply voltage is applied.
2. Power up V
CCA
.
3. V
CCB
can be ramped up along with or after V
CCA
.
Table 3. Typical Total Static Power Consumption (I
CCA
+ I
CCB
)
V
CCA
V
CCB
UNIT
0 V 1.8 V 2.5 V 3.3 V 5 V
0 V 0 <1 <1 <1 <1
1.8 V <1 <2 <2 <2 2
2.5 V <1 <2 <2 <2 <2 mA
3.3 V <1 <2 <2 <2 <2
5 V <1 2 <2 <2 <2
10 Submit Documentation Feedback Copyright © 2008–2010, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2T45-EP