Datasheet
SN74LVC2G74
www.ti.com
SCES203N –APRIL 1999–REVISED JULY 2013
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
–40°C to 125°C
–40°C to 85°C
Recommended
PARAMETER TEST CONDITIONS V
CC
UNIT
SN74LVC2G74 SN74LVC2G74
TYP
(1
MIN MAX MIN TYP MAX
)
1.65 V to 5.5
I
OH
= –100 μA V
CC
– 0.1 V
CC
– 0.1
V
I
OH
= –4 mA 1.65 V 1.2 1.2
I
OH
= –8 mA 2.3 V 1.9 1.85
V
OH
V
I
OH
= –16 mA 2.4 2.4
3 V
I
OH
= –24 mA 2.3 2.3
I
OH
= –32 mA 4.5 V 3.8 3.8
1.65 V to 5.5
I
OL
= 100 μA 0.1 0.1
V
I
OL
= 4 mA 1.65 V 0.45 0.45
I
OL
= 8 mA 2.3 V 0.3 0.3
V
OL
V
I
OL
= 16 mA 0.4 0.4
3 V
I
OL
= 24 mA 0.55 0.55
I
OL
= 32 mA 4.5 V 0.55 0.55
Data or
I
I
V
I
= 5.5 V or GND 0 to 5.5 V ±5 ±5 μA
control inputs
I
off
V
I
or V
O
= 5.5 V 0 ±10 ±10 μA
1.65 V to 5.5
I
CC
V
I
= 5.5 V or GND, I
O
= 0 10 10 μA
V
One input at V
CC
– 0.6 Other inputs at V
CC
or
ΔI
CC
3 V to 5.5 V 500 500 μA
V, GND
C
i
V
I
= V
CC
or GND 3.3 V 5 5 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
SN74LVC2G74
–40°C to 85°C
Parameter From To UNIT
V
CC
= 1.8V ±0.15V V
CC
= 2.5V ±0.2V V
CC
= 3.3V ±0.3V V
CC
= 5V ±0.5V
MIN MAX MIN MAX MIN MAX MIN MAX
f
clock
80 175 175 200 MHz
CLK 6.2 2.7 2.7 2
t
w
ns
PRE or CLR low 6.2 2.7 2.7 2
Data 2.9 1.7 1.3 1.1
t
su
ns
PRE or CLR inactive 1.9 1.4 1.2 1
t
h
0 0.3 1.2 0.5 ns
Copyright © 1999–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: SN74LVC2G74