Datasheet
SN74LVC2G14
www.ti.com
SCES200M –APRIL 1999–REVISED NOVEMBER 2013
Switching Characteristics
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
SN74LVC2G14
–40°C to 85°C
FROM TO
PARAMETER V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V V
CC
= 5 V UNIT
(INPUT) (OUTPUT)
± 0.15 V ± 0.2 V ± 0.3 V ± 0.5 V
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A Y 3.9 9.5 1.9 5.7 2 5.4 1.5 4.3 ns
Switching Characteristics
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
SN74LVC2G14
–40°C to 125°C
FROM TO
PARAMETER V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V V
CC
= 5 V UNIT
(INPUT) (OUTPUT)
± 0.15 V ± 0.2 V ± 0.3 V ± 0.5 V
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A Y 3.9 10.5 1.9 6.5 2 6.0 1.5 4.7 ns
Operating Characteristics
T
A
= 25°C
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V V
CC
= 5 V
PARAMETER TEST CONDITIONS UNIT
TYP TYP TYP TYP
C
pd
Power dissipation capacitance f = 10 MHz 16 17 18 21 pF
Copyright © 1999–2013, Texas Instruments Incorporated Submit Documentation Feedback 5