Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range 0.5 6.5 V
V
I
Input voltage range
(2)
0.5 6.5 V
V
O
Voltage range applied to any output in the high-impedance or power-off state
(2)
0.5 6.5 V
V
O
Voltage range applied to any output in the high or low state
(2) (3)
0.5 V
CC
+ 0.5 V
I
IK
Input clamp current V
I
< 0 50 mA
I
OK
Output clamp current V
O
< 0 50 mA
I
O
Continuous output current ±50 mA
Continuous current through V
CC
or GND ±100 mA
DBV package 206
DCK package 252
DRL package 142
θ
JA
Package thermal impedance
(4)
DRY package 234 °C/W
DSF package 300
YZP package 132
YZV package 123
T
stg
Storage temperature range 65 150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The value of V
CC
is provided in the recommended operating conditions table.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
(1)
MIN MAX UNIT
Operating 1.65 5.5
V
CC
Supply voltage V
Data retention only 1.5
V
I
Input voltage 0 5.5 V
V
O
Output voltage 0 V
CC
V
V
CC
= 1.65 V 4
V
CC
= 2.3 V 8
I
OH
High-level output current 16 mA
V
CC
= 3 V
24
V
CC
= 4.5 V 32
V
CC
= 1.65 V 4
V
CC
= 2.3 V 8
I
OL
Low-level output current 16 mA
V
CC
= 3 V
24
V
CC
= 4.5 V 32
T
A
Operating free-air temperature 40 85 °C
(1) All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Copyright © 20052011, Texas Instruments Incorporated 3