Datasheet
SCAS583J − NOVEMBER 1996 − REVISED FEBRUARY 2005
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
Output
(see Note C)
t
PHL
t
PLH
From
B or Y Output
Under Test
SLEW RATE A-TO-B OR A-TO-Y LOAD (Totem Pole)
VOLTAGE WAVEFORMS MEASURED AT TP1
PROPAGATION DELAY TIMES (A to B)
2.7 V
V
OH
V
OL
0 V
62 Ω
C
L
= 50 pF
(see Note A)
TP1
V
CC
C
L
= 50 pF
(see Note A)
Sink Load
Source Load
1.4 V
V
OH
− 1.4 V
62 Ω
t
PHL
t
PLH
Input
(see Note B)
Output
(see Note B)
1.4 V
V
OL
+ 1.4 V
t
w
A-TO-B LOAD OR A-TO-Y LOAD (Open Drain)
VOLTAGE WAVEFORMS MEASURED AT TP1, B SIDE
2.7 V
V
OH
V
OL
0 V
1.4 V
1.4 V
2 V 2 V
0.8 V 0.8 V
t
r
t
f
TP1
From
B or Y Output
C
L
= 50 pF
(see Note A)
500 Ω
V
CC
NOTES: A. C
L
includes probe and jig capacitance.
B. Input rise and fall times are 3 ns, 150 ns < pulse duration < 10 µs for both low-to-high and high-to-low transitions.
Slew rate is measured between 0.4 V and 0.9 V for the rising edge and between 2.4 V and 1.9 V for the falling edge.
C. Input rise and fall times are 3 ns. Rise and fall times (open drain) < 120 ns.
D. The outputs are measured one at a time, with one transition per measurement.
Input
(see Note C)
Figure 1. Load Circuits and Voltage Waveforms