absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage range: V
CC
CABLE −0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC
−0.5 V to 4.6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input and output voltage range, V
I
and V
O
: Cable side (see Notes 1 and 2) −2 V to 7 V. . . . . . . . . . . . . . . . . .
Peripheral side (see Note 1) −0.5 V to V
CC
+ 0.5 V. . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0) −20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0) −50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
: Except PERI LOGIC OUT ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERI LOGIC OUT ±100 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through each V
CC
or GND ±200 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output high sink current, I
SK
(V
O
= 5.5 V and V
CC
CABLE = 3 V) 65 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Note 3): DGG package 89°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DL package 94°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The ac input voltage pulse duration is limited to 40 ns if the amplitude is greater than −0.5 V.
3. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions (see Note 4)
MIN MAX UNIT
V
CC
CABLE Supply voltage for the cable side, V
CC
CABLE ≥ V
CC
3 5.5 V
V
CC
Supply voltage 3 3.6 V
A, B, DIR, and HD 2
V
IH
High-level input voltage
C14−C17 2.3
V
V
IH
High-level input voltage
HOST LOGIC IN
2.6
V
PERI LOGIC IN 2
A, B, DIR, and HD 0.8
V
IL
Low-level input voltage
C14−C17 0.8
V
V
IL
Low-level input voltage
HOST LOGIC IN
1.6
V
PERI LOGIC IN 0.8
V
I
Input voltage
Peripheral side 0 V
CC
V
V
I
Input voltage
Cable side
0 5.5
V
V
O
Open-drain output voltage HD low 0 5.5 V
HD high, B and Y outputs −14
I
OH
High-level output current
A outputs and HOST LOGIC OUT
−4
mA
I
OH
High-level output current
PERI LOGIC OUT −0.5
mA
B and Y outputs 14
I
OL
Low-level output current
A outputs and HOST LOGIC OUT
4
mA
I
OL
Low-level output current
PERI LOGIC OUT 84
mA
T
A
Operating free-air temperature 0 70 °C
NOTE 4: All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.